For casing set depth:
MW max is limited by prior casing shoe fracture pressure (minus kick margin).
MW min is limited by BHP (plus trip margin).

In this problem:

3,000 psi = 0.052(MWmax)4,000 ft
...so MW max = 14.4 ppg

 6,000 psi = 0.052(MWmax)9,000 ft
 ...so MW max = 12.8 + 0.2 = 13.0 ppg